Unfortunately Thermo Orion PH/RDO/COND&6M Prb 5STAR 1213322 is not listed by LabPlanet.You can also explore other items in the Conductivity meters yourself to try and find the perfect replacement for you!
Thermo Orion PH/RDO/COND&6M Prb 5STAR 1213322 is one of the many quality laboratory and scientific products we have to offer at very competitive pricing. Thermo Orion PH/RDO/COND&6M Prb 5STAR 1213322 / 97015-848 is part of a wide selection of Thermo Orion Conductivity meters. Combining excellent quality with an affordable price, the Thermo Orion PH/RDO/COND&6M Prb 5STAR 1213322 / 97015-848 can meet your scientific research needs while still offering a good value for a budget conscious end user. If you have any questions about any of our Conductivity meters please do not hesitate to contact our customer service for further guidance.
Meter features an RDO (Rugged Dissolved Oxygen) sensor that utilizes optical DO technology and requires no membranes, just a simple yearly cap replacement. Ideal for measuring the pH, DO, conductivity, and temperature of effluent, aeration basins, and even influent, since the sensor is not affected by color or turbidity.
Meter allows pH calibration of up to five points with calibration alarm and automatic buffer recognition of USA, NIST, and DIN buffers, temperature calibration capability for pH and conductivity, and automatic salinity correction for DO measurements from the conductivity probe reading. Conductivity, TDS, salinity, and resistivity calibration of up to five points and reading reference temperatures of 5°C, 10°C, 15°C, 20°C, or 25°C.
Up to 500 data sets can be stored along with time and date stamping. Calibrate for dissolved oxygen using water-saturated air, air-saturated water, zero point, or at a custom point with Winkler titration. Built-in barometer provides automatic pressure correction with option for manual input. RS-232 port allows easy data downloading and software updates. Measured values are simultaneously displayed on a backlit LCD screen.
ASTM D888-05 Method C compliant. Housing and backlit display are IP67-rated. RDO sensor is IP68-rated.
Dissolved Oxygen, | ||
Concentration Range: | 0.00-20.0 mg/L | |
Resolution: | 0.01, 0.1 mg/L | |
Relative Accuracy: | ±0.1 mg/L, up to 8 mg/L; | |
±0.2 mg/L from 8-20 mg/L | ||
% Saturation Range: | 0.0-200% | |
Resolution: | 0.1, 1% | |
Relative Accuracy: | ±2% | |
Barometric Pressure Correction: | 450-850 mm Hg (automatic or manual) | |
pH, | ||
Range: | -2.000-19.999 | |
Resolution: | 0.1, 0.01, 0.001 | |
Relative Accuracy: | ±0.002 | |
mV; RmV; ORP, | ||
Range: | ±1999.9 mV | |
Resolution: | 0.1 mV | |
Relative Accuracy: | ±0.2 mV or 0.05% of reading, whichever is greater | |
Conductivity, | ||
Range: | 0.000 to 3.000 mS/cm (auto resolution, cell constant dependent) | |
Resolution: | 4 significant digits, down to 0.001 uS/cm, whichever is greater | |
Cell Constants: | 0.001 to 199.9 cm-1 | |
Resistivity, | ||
Range: | 0.0001 to 100 Megohm | |
Relative Accuracy: | 0.5% ±1 digit | |
Salinity, | ||
Range: | 0.1-80 ppt NaCl equivalent, 0.1-42 ppt practical salinity | |
Resolution: | 0.1 ppt | |
Relative Accuracy: | ±0.1 ±1 digit | |
TDS, | ||
Range: | 0-19,999 mg/L | |
Resolution: | 1 mg/L | |
Relative Accuracy: | ±0.5%, ±1 digit | |
Temperature, | ||
Range: | 0 to 50° (with RDO sensor); -5 to 105°C (without RDO sensor) | |
Resolution: | 0.1°C (with RDO sensor); 0.1°C up to 99.9°C, 1.0 over 99.9°C (without RDO sensor); | |
Relative Accuracy: | ±0.3°C (with RDO sensor); | ±0.1°C (without RDO sensor) |
Description: | Meter with 6 m (19.7') Probe Kit |
Thermo Scientific No.: | 1213322 |
Unit: | Each |